[Product Introduction]

Main technical indicators of black body: black body emissivity, black body cavity diameter, temperature uniformity and radiation temperature uncertainty.

So in order to ensure the quality of black body products, usually black body is designed according to the temperature segment.

Usually what we call boldface is artificial boldface.

The emissivity of the artificial blackbody is close to, but not equal to, 1.

The main function of the black body is to produce standard radiation at a given temperature.

Therefore in the temperature measurement is mainly used to verify a variety of radiation thermometers, such as optical pyrometer, infrared thermometer, infrared thermograph and so on.

Black body in the industry is mainly used in the field of temperature measurement, the main product is black body furnace.

In the calibration and verification of radiation thermometers, the comparative method is usually adopted, that is, through the radiation source of high stability (usually black body radiation source) and other supporting equipment, the temperature reproduced by the standard apparatus and the temperature reproduced by the radiation thermometer are compared, in order to judge whether it is qualified or to give the calibration results.

As a standard radiation source, the standard black body is mainly used to calibrate radiation thermometers, infrared thermometers and radiation temperature sensing detectors.

At present, our company has advanced black body technology, full product range and wide temperature range of black body series products.

The product is small in size, light in weight and easy to carry. It is not only suitable for the use of radiation thermometers in the laboratory calibration of measuring institutions at all levels, but also for on-site calibration.

[Product Features]

1. Human-machine interface, Chinese display, touch operation, beautiful and generous.

2. One-key temperature setting, easy to operate.

Rapid heating, temperature control.

3. Can copy the language interface of many countries according to customer requirements for export convenience.

Product advantage

1) Novel appearance design, the use of furnace body and temperature control instrument separated structure.

2) Isothermal black body cavity, only one cavity mouth, cavity mouth radiation evenly distributed along with the spectrum, cavity mouth emissivity above 0.995, the resolution of 0.1.

3) Heat insulation between the heating body and the shell, special software is used for pressure limiting heating, no high-power power transformer is required.

4) Automatic temperature control is adopted, which is safe and reliable with fast temperature rise and good temperature stability.

5) Easy to operate, small in size and light in weight, easy to carry, suitable not only for laboratory calibration, but also for on-site calibration.

[Technical Indicators]

Operating temperature: -100℃~80℃

Operation mode: touch screen operation

Temperature resolution: 0.1℃

Temperature control: PID automatic control

Mouth cavity diameter: Φ 50 mm

Cavity and mouth emissivity: ≥0.995

Temperature stability: t is the radiation source temperature if the temperature is not greater than 0.1℃ and 0.1% T

Temperature uniformity: not greater than ± (0.15℃ and 0.15% T, t is the radiation source temperature)

Power supply: 220 vac50hz

Power: 1600 w

Size: 610*280*410mm(length x width x height)

Weight: 20 kg

Note: other special requirements can be customized according to the needs of users

Operation interface

DY-HT1D Ultra-low Temperature Blackbody Furnace

DY-HT1D Ultra-low Temperature Blackbody Furnace

DY-HT1D Ultra-low Temperature Blackbody Furnace

DY-HT1D Ultra-low Temperature Blackbody Furnace(-100℃~80℃) 2020-12-8 This article was read 3900 Times
Previous:PartnerNext:Partner

Technical

Contact us

Taian Demei Electromechanical Equipment Co.,LTD.

Address:No. 8, Hedong Road, Shengzhuang Town, Taishan District, Taian, Shandong,China (Mainland)

Tel: +86-538-6518016 / 6518018

Mobile: +86-186 5382 5886

Whatsapp: +86-186 5382 5886   Skype: +86 186 5382 5886

Contact: Grace   Email: grace@demeithermo.com

Sales network

Taian Demei Electromechanical Equipment Co.,LTD.             Lu ICP No. 14019246-4             Publicity