DY-BM02 Surface Thermometer Calibration Furnace

DY-BM02 Surface Thermometer Calibration Furnace

DY-BM02 Surface Thermometer Calibration Furnace

◇ Product Introduction ◇ Product Features◇ Technical Indicator

[Product Introduction]

With the development of science and technology, contact surface thermometers are widely used in aerospace, energy, electromechanical, chemical, textile, electric power and other fields, so the calibration and measurement needs of surface thermometers are increasing.

DY - BM02 surface thermometer calibration furnace is developed by taian german-american mechanical and electrical equipment co., LTD. Production of the new temperature calibration equipment, this equipment according to the actual demand, expanding to a temperature of 600 ℃, solved the high temperature surface temperature sensor cannot be traced back problem, it is mainly used for calibration of various type and size of the sensor surface, such as thermistors, thin film sensors, surface resistance thermometer, strip temperature sensor, surface thermocouple.

The calibrator rises and drops quickly, from room temperature to 600 ℃ within 40 minutes; The actual test technical indicators meet the standard requirements of "JJF1409-2013 Surface Thermometer Calibration Specifications", and some technical parameters are better than the imported similar products.

[Product Features]

 the temperature control system and temperature source furnace system layout;

 for 7 inch touch screen man-machine dialogue interface, human-machine interactive dialog more friendly, more clear, easy to operate;

 with fine alloy new material as heat conducting plate, with high thermal conductivity, good thermal performance, good oxidation resistance, corrosion resistance is strong, good uniformity, etc;

 using uniform heating plate, improve the uniformity and stability of the heat source, to ensure the work area uniformity of temperature field.

[Technical indicators]

1. Temperature range: ring temperature +5℃~600.0℃

2. accuracy: ±0.5℃@200 ℃; Plus or minus 1.0 ℃ @ 400 ℃; Plus or minus 1.5 ℃ @ 600 ℃

3. Stability: ±0.2℃@300℃; Plus or minus 0.3 ℃ @ 400 ℃; Plus or minus 1.0 ℃ @ 600 ℃

4. Resolution: 0.1℃

5. Uniformity: ≤0.5℃@100℃; 0.6 ℃ @ 200 ℃ or less; 0.8 ℃ @ 300 ℃ or less; 1.0 ℃ @ 400 ℃ or less; 2.0 ℃ @ 600 ℃ or less

6. Heating time: 40min (room temperature to 600℃)

7. Cooling time: 60min (600℃ to 100℃)

8. Stabilization time: ≤8min

9. Measuring surface: ¢100mm

10. Power consumption: 1000W

DY-BM02 Surface Thermometer Calibration Furnace 2020-12-9 This article was read 3389 Times
Previous:PartnerNext:Partner

Technical

Contact us

Taian Demei Electromechanical Equipment Co.,LTD.

Address:No. 8, Hedong Road, Shengzhuang Town, Taishan District, Taian, Shandong,China (Mainland)

Tel: +86-538-6518016 / 6518018

Mobile: +86-186 5382 5886

Whatsapp: +86-186 5382 5886   Skype: +86 186 5382 5886

Contact: Grace   Email: grace@demeithermo.com

Taian Demei Electromechanical Equipment Co.,LTD.             Lu ICP No. 14019246-4             Publicity